Input Power Voltage VDD: | 24V | Input Current ICC: | 1.0 A |
---|---|---|---|
Input Signal High Level: | DD V | Max Inhalation Current Of Output/terminal: | 0.3A |
High Light: | vision measurement system,vision measuring systems |
Description
UWC348 is a IO communication card with 24 IN and 24 OUT. Power by a 24V input power source. Communicating with the PC through RS232 signal. The input is low level effective, output is open drain output. The current can reach to 500mA per circuit. Max voltage is 24V.
Features
1. Using RS232 communication, port rate is 115200, ensure fast communication.
2. UWCL communication protocol, the communication data is stable and reliable.
3. Software developing package and demo source code are offered, easy for continuous developing.
4. PCI socket is not required, easy to use.
5. Advanced design and assembling technology, low error.
Application
Operation controlling application which required switches, sensor, high low level detecting, solenoid valve, electromagnet, relay or indicators etc.
Specification
Min. |
Max. |
Typical |
Unit |
|
Input power voltage VDD |
10 |
27 |
24 |
V |
Input current ICC |
- |
- |
1.0 |
A |
Input signal high level |
VDD-3 |
VDD+3 |
DD |
V |
Input signal low level |
0 |
3 |
- |
V |
Input power voltage VDD |
- |
0.3/terminal |
- |
A |
Output total inhalation current |
- |
5 |
- |
A |
Output turn-on voltage drop |
0 |
1.4 |
1.1 |
V |
Output bearing voltage |
- |
VDD+0.3 |
DD |
V |